Understand the Importance of Fire Alarm System in Your Building
The next time you step into your building, we suggest you step to the side and take a few seconds to look up at your roof and next to the doors. Take note of the smoke detectors, pull stations and the red board that is behind the receptionist’s desk. Then stroll down the hallway and continue filtering for anything on the roof that looks like a strobe, horn strobe and more pull station sat the ways out. Finally, walk to your electrical room or sprinkler room and you will probably discover your Fire Alarm Control Panel (FACP).
When you take the key and open the board; you will discover the installation date, review date and any repairs that have been performed; documented and put in the entryway. This is an extraordinary place to start your look for whom to call if your system is failing. The installation companies name will be on the highest of the installation sticker. They likely have an assessment and administration division that can repair your system.
Now that you have opened your board, you should take note of a few things instantly. First, does the panel show system normal or something to that end? Second, does the board have a sticker in it demonstrating that it has received its annual inspection this year? Third, take note of the two batteries at the base of the FACP; these batteries must have the month and year of their installation written on them so that you will know when they must be replaced.
HERE ARE SOME COMMON FAULTS AND WHAT THEY MEAN
1. Ground Fault – This implies that an electrical component is reaching contact with something that it must not be making contact with.
2. Low Battery – This implies that your batteries are low and likely should be replaced.
3. Digital Alarm Communicator Transmitter (DACT) – These have the ability to dial out or send a digitized message to a central station that will transfer the message to a fire station or advise designated personnel in regard to a trouble in your system. This being a trouble implies that your fire alarm system is not communicating completely.
4. Panel Beeping and you don’t even care why!!! – This is where prior planning comes in extremely helpful. Call your fire alarm inspection and Service Company, have them send an expert to your building as soon as possible, they will settle the system for you. Your fire alarm system has inputs and outputs. Smoke detectors, beam detectors, and heat detectors are basic inputs. Strobes and horn strobes are normal outputs. When an input detects something that will place it into alarm for an example: fire, smoke or heat a signal is sent to the FACP. This signal will then be utilized to send the notification gadgets into alarm. Meanwhile, if your system is going into alarm, your DACT will be dialing out to the observing station who will then advise the proper personnel.
If you need particular information about your fire alarm system you can usually visit Qutak and download the client manual after looking at your FACP to discover out what type of system you have. You can also request for quotation for fire alarm with an optimal price.